• 01279 430831
  • Contact us
  • Recently added item(s) ×

    You have no items in your shopping basket.

Solarmeter 5.0 UVA/UVB Radiometer mW
£177.00

Be the first to review this product

In stock

RRP £208.00 Save £31.00

Order within the next 34 hours 52 minutes to receive your order on Monday next week !

Earn 177 Points Loyalty Points when buying this product.

OR
Description

Details

 

 




  • Model 5.0 HP > 0-1999 mW/cm²
    (For high pressure lamps over 199.9 mW/cm²)


    Model 5.0 SF > 0-199.9 W/m²
    (For science fair projects)

    Sensor
    Hamamatsu #G5842 UV SENSOR/FILTER
    The G5842 is a semiconductor UV sensor consisting of a GaAsP photodiode chip and a UV filter. The G5842 is completely insensitive to visible light longer than 400 nm and infrared radiation since its spectral response covers only the UV region from 260 to 400 nm. Applications of the G5842 include solar UV detection, as the spectral response is well matched to the solar UV spectrum, and tanning lamps peaking near 365 nm ("new era" fluorescent and "high pressure" HID).

    Operation
    Press and hold push-button switch on face of unit. Aim sensor window in top panel of meter directly at UV source. Note reading on LCD and record if desired.

    Battery operation voltage is 9V down to 6.5V. Below 6.5V the LCD numbers will begin to dim, indicating the need for battery replacement. Under "typical" service load, the battery should last about 2 years.

    Proper Usage of Solarmeter ® Ultraviolet Radiometer for Lamp Aging Tests

    • Wear eye protection when checking UV lamps (UV-block wrap around glasses)
    • Allow lamps to warm-up prior to taking readings (at least 5 min).
    • When checking aging of lamps, keep measuring distance and locations constant.
    • Lamps should be replaced when output drops to about 70% of their original (new) readings. Take overall reading at center of tanning bed bench pointing up with canopy closed, or check individual lamps at acrylic with canopy up. Keep track of hours vs. readings on a chart.
    • If unsure of what original new values were, replace two adjacent lamps with new ones of the same kind and compare old ones.
    • This meter is primarily "seeing" the UVA "browning" rays. For erythemal rays use Model 7.0 MED/hr meter to relate to Te time.
    • When checking acrylic transmission, take reading through acrylic; then remove acrylic and hold meter sensor at approximately the same distance from lamp as the acrylic shield was located. Note: Model 6.0 UVB meter is better for this purpose).
    • When using this meter to compare different types of lamps, due to their different spectral power distributions, the readings should be considered relative rather than absolute. Although higher output lamps of similar SPD's will read higher than low output lamps, ones that peak near 365 nm (as does the meter response) will read higher than ones peaking near 350 nm even if the total UV output of both is the same.
    • Do not subject the meter to extremes in temperature, humidity, shock or dust.
    • Use a dry, soft cloth to clean the intrument. Keep sensor free of oil, dirt, etc. 
  •  

    Product Reviews

    Write Your Own Review

    You're reviewing: Solarmeter 5.0 UVA/UVB Radiometer mW

    How do you rate this product? *

     
    1 1 star
    2 2 star
    3 3 star
    4 4 star
    5 5 star
    Quality
    Price
    Value